Torque & Power Supply Feature - 50-60Hz AC or DC

Open-Close Duty

Short-Time Duty (S2-15’) | Inching Duty (S4-25% |60 St/h)

 

Output Torque(4)Nm / lbf-ft

 

Operating Speed (RPM)/Motor Type

 

 

Hz

Type

12

18

24

36

48

72

144

50

 

Minimum

Nominal

14

22

29

43

58

86

173

60

ICON 010 12 / 9 30 / 22 SM00 SM01 SM10 SM03 SM04 SM05 SM06 -
ICON 010 36 / 27 90 / 66 SM10 SM11 SM12 SM13 SM14 SM15 SM16 -
ICON 020 72 / 53 180 / 133 - SM13 SM14 SM15 SM21 SM22 SM23 -
ICON 030 144 / 106 360 / 266 SM21 SM32 SM21 - SM30 SM23 SM31 -
ICON 040 288 / 212 720 / 531 SM30 SM44 SM30 SM40 SM41 SM31 SM42 -
ICON 050 576 / 425 1440 / 1062 SM41 SM40 SM41 SM43 SM50 SM42 SM51 -

 

Short-Time Duty (S2-30’)

 

Output Torque(4)Nm / lbf-ft

 

Operating Speed (RPM)/Motor Type

 

 

Hz

Type

12

18

24

36

48

72

144

50

 

Minimum

Nominal

14

22

29

43

58

86

173

60

ICON 010 12 / 9 30 / 22 TM00 TM01 TM10 TM03 TM04 TM05 TM06 -
ICON 010 36 / 27 90 / 66 TM10 TM11 TM12 TM13 TM14 TM15 TM16 -
ICON 020 72 / 53 180 / 133 - TM13 TM14 TM15 TM21 TM22 TM23 -
ICON 030 144 / 106 360 / 266 - - TM21 - TM30 TM23 TM31 -
ICON 040 288 / 212 720 / 531 - - TM30 TM40   TM31

-

-

 

Note

  1. Output torque: Adjustable in OPEN and in CLOSED direction from minimum to nominal values.
  2. Electric data actuator: Refer to FCDS-20149-EN with reference to the Power supply and Motor type.
  3. SMxx or TMxx: Code of the electric motor applied to the actuator model.
  4. Stall Torque will be up to 2 times the Nominal Torque depending on speed and voltage. Maximum torque/thrust that electric actuator develops when the motor is energized and the output drive is locked.

 

Modulating Duty
Intermittent Periodic Duty (S4-25% - 600 St/h)

 

Output Torque(4)Nm / lbf-ft

 

Operating Speed (RPM)/Motor Type

 

 

Hz

Type

12

18

24

36

48

72

144

50

 

Minimum

Nominal

14

22

29

43

58

86

173

60

ICON 010 12 / 9 30 / 22 TM00 TM01 TM10 TM03 TM04 TM05 TM06 -
ICON 010 36 / 27 90 / 66 TM10 TM11 TM12 TM13 TM14 TM15 TM16 -
ICON 020 72 / 53 180 / 133 - TM13 TM14 TM15 TM21 TM22 TM23 -
ICON 030 144 / 106 360 / 266 - - TM21 - TM30 TM23 TM31 -
ICON 040 288 / 212 720 / 531 - - TM30 TM40 - TM31 - -

 

Intermittent Periodic Duty (S4-50% - 1200 St/h)

 

 

Output Torque(4)Nm / lbf-ft

 

Operating Speed (RPM)/Motor Type

 

 

Hz

Type

12

18

24

36

48

72

144

50

 

Minimum

Nominal

14

22

29

43

58

86

173

60

ICON 010R 12 / 9 30 / 22 TM00 TM01 TM10 TM03 TM04 TM05 - -
ICON 010R 36 / 27 90 / 66 TM10 TM11 TM12 TM13 TM14 TM15 - -
ICON 020R 72 / 53 180 / 133 - TM13 TM14 TM15 TM21 TM22 - -
ICON 030R 144 / 106 360 / 266 - - TM21 - TM30 - - -
ICON 040R 288 / 212 720 / 531 - - TM30 - - - - -

 

Note:

  • Output torque: Adjustable in OPEN and in CLOSED direction from minimum to nominal values.
  • Electric data actuator: Refer to FCDS-20149-EN with reference to the Power supply and Motor type.
  • SMxx or TMxx: Code of the electric motor applied to the actuator model.
  • Stall Torque will be up to 2 times the Nominal Torque depending on speed and voltage. Maximum torque/thrust that electric actuator develops when the motor is energized and the output drive is locked.

 

Modulating Duty
Intermittent Periodic Duty (S4-25% - 600 St/h)

 

Output Torque(4)Nm / lbf-ft

 

Operating Speed (RPM)/Motor Type

 

 

Hz

Type

12

18

24

36

48

72

144

50

 

Minimum

Nominal

14

22

29

43

58

86

173

60

ICON 010 12 / 9 30 / 22 TM00 TM01 TM10 TM03 TM04 TM05 TM06 -
ICON 010 36 / 27 90 / 66 TM10 TM11 TM12 TM13 TM14 TM15 TM16 -
ICON 020 72 / 53 180 / 133 - TM13 TM14 TM15 TM21 TM22 TM23 -
ICON 030 144 / 106 360 / 266 - - TM21 - TM30 TM23 TM31 -
ICON 040 288 / 212 720 / 531 - - TM30 TM40 - TM31 - -

 

Intermittent Periodic Duty (S4-50% - 1200 St/h)

 

 

Output Torque(4)Nm / lbf-ft

 

Operating Speed (RPM)/Motor Type

 

 

Hz

Type

12

18

24

36

48

72

144

50

 

Minimum

Nominal

14

22

29

43

58

86

173

60

ICON 010R 12 / 9 30 / 22 TM00 TM01 TM10 TM10 TM10 TM05 - -
ICON 010R 36 / 27 90 / 66 TM10 TM11 TM12 TM13 TM14 TM15 - -
ICON 020R 72 / 53 180 / 133 - TM13 TM14 TM15   TM22    
ICON 030R 144 / 106 360 / 266 - - TM21 - TM30 - - -
ICON 040R 288 / 212 720 / 531 - - TM30 - - - - -

Note:

  • Output torque: Adjustable in OPEN and in CLOSED direction from minimum to nominal values.
  • Electric data actuator: Refer to FCDS-20149-EN with reference to the Power supply and Motor type.
  • SMxx or TMxx: Code of the electric motor applied to the actuator model.
  • Stall Torque will be up to 2 times the Nominal Torque depending on speed and voltage. Maximum torque/thrust that electric actuator develops when the motor is energized and the output drive is locked.

 Power Supply Single-Phase AC

Open-Close Duty - Short-Time Duty (S2-15’) | Inching Duty (S4-25% |60 St/h) Power Supply 220/230/240 V, 50/60 Hz

 

Output Torque(4)Nm / lbf-ft

 

Operating Speed (RPM)/Motor Type

Type

 

 

 

 

 

Minimum

Nominal

From

To

Motor

ICON 010 12 / 9 30 / 22 8 17 TM11
ICON 010 12 / 9 30 / 22 24 72 TM15
ICON 010 12 / 9 30 / 22 73 172 TM16
ICON 010 36 / 27 90 / 66 6 23 TM13
ICON 010 36 / 27 90 / 66 24 95 TM18
ICON 010 36 / 27 90 / 66 96 120 TM16
ICON 020 72 / 53 180 / 133 12 36 TM22
ICON 020 72 / 53 180 / 133 48 60 TM22
ICON 030 144 / 106 360 / 266 10 30 TM30

 

Power Supply 110/115/120 V, 50/60 Hz

 

Output Torque(4)Nm / lbf-ft

 

Operating Speed (RPM)/Motor Type

Type

 

 

 

 

 

Minimum

Nominal

From

To

Motor

ICON 010 12 / 9 30 / 22 8 17 TM11
ICON 010 12 / 9 30 / 22 18 62 TM14
ICON 010 12 / 9 30 / 22 63 94 TM15
ICON 010 36 / 27 90 / 66 6 23 TM13
ICON 010 36 / 27 90 / 66 24 40 TM14
ICON 020 72 / 53 180 / 133 8 20 TM21

 

  • Output torque: Adjustable in OPEN and in CLOSED direction from minimum to nominal values.
  • Electric data actuator: Refer to FCDS-20149-EN with reference to the Power supply and Motor type.
  • SMxx or TMxx: Code of the electric motor applied to the actuator model.
  • Stall Torque will be up to 2 times the Nominal Torque depending on speed and voltage. Maximum torque/thrust that electric actuator develops when the motor is energized and the output drive is locked.

 

Modulating Duty - Intermittent Periodic Duty (S4-50% - 1200St/h) Power Supply 220/230/240 V, 50/60 Hz

 

Output Torque(4)Nm / lbf-ft

 

Operating Speed (RPM)/Motor Type

Type

 

 

 

 

 

Minimum

Nominal

From

To

Motor

ICON 010R 12 / 9 30 / 22 8 17 TM11
ICON 010R 12 / 9 30 / 22 24 72 TM15
ICON 010R 12 / 9 30 / 22 73 172 TM16
ICON 010R 36 / 27 90 / 66 6 23 TM13
ICON 010R 36 / 27 90 / 66 24 95 TM18
ICON 020R 72 / 53 180 / 133 12 36 TM22
ICON 020R 72 / 53 180 / 133 48 60 TM22
ICON 030R 144 / 106 360 / 266 10 30 TM30

 

 

Power Supply 110/115/120 V, 50/60 Hz

 

Output Torque(4)Nm / lbf-ft

 

Operating Speed (RPM)/Motor Type

Type

 

 

 

 

 

Minimum

Nominal

From

To

Motor

ICON 010R 12 / 9 30 / 22 8 17 TM11
ICON 010R 12 / 9 30 / 22 18 62 TM14
ICON 010R 12 / 9 30 / 22 63 94 TM15
ICON 010R 36 / 27 90 / 66 6 23 TM13
ICON 010R 36 / 27 90 / 66 24 40 TM14
ICON 020R 72 / 53 180 / 133 8 20 TM21

 

Note:

  • Output torque: Adjustable in OPEN and in CLOSED direction from minimum to nominal values.
  • Electric data actuator: Refer to FCDS-20149-EN with reference to the Power supply and Motor type.
  • SMxx or TMxx: Code of the electric motor applied to the actuator model.
  • Stall Torque will be up to 2 times the Nominal Torque depending on speed and voltage. Maximum torque/thrust that electric actuator develops when the motor is energized and the output drive is locked.

Power Supply Direct Current

Power Supply Direct Current

 

Output Torque(4)Nm / lbf-ft

 

Operating Speed (RPM)/Motor Type

Type

 

 

 

 

 

Minimum

Nominal

From

To

Motor

ICON 010D 12 / 9 30 / 22 12 29 DM05d
ICON 010D 12 / 9 30 / 22 30 60 DM05d
ICON 010D 36 / 27 90 / 66 12 29 DM05
ICON 010D 36 / 27 90 / 66 24 30 DM05
ICON 010D 36 / 27 90 / 66 50 68 DM05

 

Note:

  • Output torque: Adjustable in OPEN and in CLOSED direction from minimum to nominal values.
  • Electric data actuator: Refer to FCDS-20149-EN with reference to the Power supply and Motor type.
  • SMxx or TMxx: Code of the electric motor applied to the actuator model.
  • Stall Torque will be up to 2 times the Nominal Torque depending on speed and voltage. Maximum torque/thrust that electric actuator develops when the motor is energized and the output drive is locked.

 

 

favicon bacd

+(39) 347 051 5328

Italy - Kazakhstan

09.00am to 18.00pm

About

We offer the best and economical solutions, backed by 27+ years of experience and international standards knowledge, echnological changes, and industrial systems.

Marketing Materials

Spring Renovation
Industry
US Gas Company
Construct
Plus Project
Vam Drilling Service
X Project
X Project
Cabrrus Training

Marketing Materials1

Spring Renovation
Industry
US Gas Company
Construct
Plus Project
Vam Drilling Service
ultrasonic sensor
ultrasonic sensor
Cabrrus Training