3051S2TG5A2E11A1AB4M5Q4P1 Rosemount 3051S Scalable Pressure Transmitter

Technical parameters
Manufacturer : Rosemount Product No. : 3051S2TG5A2E11A1AB4M5Q4P1 Product type : 3051S Scalable Pressure Transmitter Performance class : 2 = Classic: 0.035% span accuracy, 150:1 rangedown, 15-yr stability Connection type : T = In-line Measurement type : G = Gage Pressure range : 4A = –14.7 to 10000 psi (–1.01 to 689.47 bar) Isolating diaphragm : 2 = 316L SST Process connection : E11 = 1/2–14 NPT female Transmitter output : A = 4–20 mA with digital signal based on HART Protocol Housing style : 1A = PlantWeb housing, Aluminum Material, 1/2–14 NPT Conduit entry size Mounting bracket : B4 = Bracket, all SST, 2-in. pipe and panel Display Type : M5 = PlantWeb LCD display Calibration certification : Q4 = Calibration certificate Pressure testing : P1 = Hydrostatic testing with certificate Weight : 1.7 + 0.6 + 0.4 Kg Shipping weight : 8 Kg
Instrument Datasheet
Manifold Datasheet
Ordering information
|
Code
|
Model - Description - 3051S2TG4A2E11A1AB4M5Q4P1
|
|
3051S
|
Scalable pressure transmitter
|
|
Code
|
Performance class - Description
|
|
1
|
Ultra: 0.025% span accuracy, 200:1 rangedown, 15-year stability, 15-year limited warranty
|
|
2
|
Classic: 0.035% span accuracy, 150:1 rangedown, 15-year stability
|
|
Code
|
Connection type - Description
|
|
T
|
In-line
|
|
Code
|
Measurement type - Description
|
|
G
|
Gauge
|
|
A
|
Absolute
|
|
Code
|
Pressure range - Description
|
|
Gauge
|
Absolute
|
|
1A
|
–14.7 to 30 psi (–1.01 to 2.06 bar)
|
0 to 30 psia (2.06 bar)
|
|
2A
|
–14.7 to 150 psi (–1.01 to 10.34 bar)
|
0 to 150 psia (10.34 bar)
|
|
3A
|
–14.7 to 800 psi (–1.01 to 55.15 bar)
|
0 to 800 psia (55.15 bar)
|
|
4A
|
–14.7 to 4000 psi (–1.01 to 275.79 bar)
|
0 to 4000 psia (275.79 bar)
|
|
5A
|
–14.7 to 10000 psi (–1.01 to 689.47 bar)
|
0 to 10000 psia (689.47 bar)
|
|
Code
|
Isolating diaphragm - Description
|
|
2
|
316L SST
|
|
3
|
Alloy C-276
|
|
Code
|
Process connection - Description
|
|
A11
|
Assemble to Rosemount 306 integral manifold
|
|
B11
|
Assemble to one Rosemount 1199 seal
|
|
E11
|
½–14 NPT female
|
|
G11
|
G½ A DIN 16288 male (range 1–4 only)
|
|
H11
|
Coned and threaded, compatible with autoclave type F-250-C (range 5A only)
|
|
F11
|
Non-threaded instrument flange (I-flange) (range 1–4 only)
|
|
Code
|
Transmitter output - Description
|
|
A
|
4–20 mA with digital signal based on HART® protocol
|
|
F
|
FOUNDATION™ Fieldbus protocol
|
|
X
|
Wireless (requires wireless options and wireless Plantweb™ housing)
|
|
Code
|
Housing style - Description
|
Material
|
Conduit entry size
|
|
00
|
None (SuperModule™ spare part, order output code A)
|
N/A
|
N/A
|
|
1A
|
Plantweb™ housing
|
Aluminum
|
½–14 NPT
|
|
1B
|
Plantweb housing
|
Aluminum
|
M20 x 1.5
|
|
1J
|
Plantweb housing
|
SST
|
½–14 NPT
|
|
1K
|
Plantweb housing
|
SST
|
M20 x 1.5
|
|
5A(1)
|
Wireless Plantweb housing
|
Aluminum
|
½–14 NPT
|
|
5J(1)
|
Wireless Plantweb housing
|
SST
|
½–14 NPT
|
|
2E
|
Junction box housing with output for remote display and interface
|
Aluminum
|
½–14 NPT
|
|
2F
|
Junction box housing with output for remote display and interface
|
Aluminum
|
M20 x 1.5
|
|
2M
|
Junction box housing with output for remote display and interface
|
SST
|
½–14 NPT
|
|
1C
|
Plantweb housing
|
Aluminum
|
G½
|
|
1L
|
Plantweb housing
|
SST
|
G½
|
|
2G
|
Junction box housing with output for remote display and interface
|
Aluminum
|
G½
|
Wireless options
|
Code
|
Update rate - Description
|
|
WA
|
User configurable update rate
|
|
Code
|
Operating frequency and protocol - Description
|
|
3
|
2.4 GHz DSSS, IEC 62591 (WirelessHART)
|
|
Code
|
Omni-directional wireless antenna - Description
|
|
WK
|
External antenna
|
|
WM
|
Extended range, external antenna
|
|
WJ
|
Remote antenna
|
|
WN
|
High-gain, remote antenna
|
|
Code
|
SmartPower™ Housing Cover - Description
|
|
1
|
Standard Life Black Power Module (I.S. Power Module sold separately)
|
|
2
|
Extended Life Blue Power Module (I.S. Power Module sold separately)
|
Additional options
|
Code
|
HART® Revision configuration (requires HART Protocol output code A - Description
|
|
HR7
|
Configured for HART Revision 7
|
|
Code
|
Extended product warranty - Description
|
|
WR3
|
3-year limited warranty
|
|
WR5
|
5-year limited warranty
|
|
Code
|
Plantweb control functionality - Description
|
|
A01
|
FOUNDATION Fieldbus advanced control function block suite
|
|
Code
|
Diagnostics suite - Description
|
|
D01
|
FOUNDATION™ Fieldbus diagnostics suite (Process Intelligence, Plugged Impulse Line diagnostic)
|
|
DA2
|
Advanced HART® diagnostics suite (Process Intelligence, Loop Integrity, Plugged Impulse Line diagnostic, Process Alerts, Service Alerts, Variable Log, Event Log)
|
|
Code
|
Mounting bracket - Description
|
|
B4
|
Bracket, all SST, 2-in. pipe and panel
|
|
BE
|
316SST B4-style bracket with 316SST bolting
|
|
Code
|
Software configuration - Description
|
|
C1
|
Custom software configuration (requires Configuration Data Sheet)
|
Alarm limit
|
Code
|
Alarm limit - Description
|
|
C4
|
NAMUR alarm and saturation levels, high alarm
|
|
C5
|
NAMUR alarm and saturation levels, low alarm
|
|
C6
|
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
|
|
C7
|
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
|
|
C8
|
Low alarm (standard Rosemount alarm and saturation levels)
|
|
Code
|
Hardware adjustments - Description
|
|
D1
|
Hardware adjustments (zero, span, alarm, security)
|
|
Code
|
Custody transfer - Description
|
|
D3
|
Measurement Canada accuracy approval
|
|
Code
|
Ground screw - Description
|
|
D4
|
External ground screw assembly
|
Conduit plug
|
Code
|
Conduit plug - Description
|
|
DO
|
316 SST conduit plug
|
★
|
Product certifications
|
Code
|
Product certifications - Description
|
|
E1
|
ATEX Flameproof
|
|
I1
|
ATEX Intrinsic Safety
|
|
IA
|
ATEX FISCO Intrinsic Safety (FOUNDATION™ Fieldbus protocol only)
|
|
N1
|
ATEX Type n
|
|
K1
|
ATEX Flameproof, Intrinsic Safety, Type n, Dust
|
|
ND
|
ATEX Dust
|
|
E4
|
Japan Flameproof
|
|
I4(1)
|
Japan Intrinsic Safety
|
|
E5
|
USA Explosion-proof, Dust Ignition-proof
|
|
I5
|
USA Intrinsically Safe; Nonincendive
|
|
IE
|
USA FISCO Intrinsically Safe (FOUNDATION Fieldbus protocol only)
|
|
K5
|
USA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
|
|
E6
|
Canada Explosion-proof, Dust Ignition-proof, Division 2
|
|
I6
|
Canada Intrinsically Safe
|
|
IF
|
Canada FISCO Intrinsically Safe (FOUNDATION Fieldbus protocol only)
|
|
K6
|
Canada Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
|
|
E7
|
IECEx Flameproof, Dust
|
|
I7
|
IECEx Intrinsic Safety
|
|
IG
|
IECEx FISCO Intrinsic Safety (FOUNDATION Fieldbus protocol only)
|
|
N7
|
IECEx Type n
|
|
K7
|
IECEx Flameproof, Dust, Intrinsic Safety, Type n
|
|
E2
|
Brazil Flameproof
|
|
I2
|
Brazil Intrinsic Safety
|
|
IB
|
Brazil FISCO Intrinsic Safety
|
|
K2
|
Brazil Flameproof, Intrinsic Safety
|
|
E3
|
China Flameproof
|
|
I3
|
China Intrinsic Safety
|
|
N3
|
China Type n
|
|
EP
|
Korea Flameproof
|
|
IP
|
Korea Intrinsic Safety
|
|
KP
|
Korea Flameproof, Intrinsic Safety
|
|
EM
|
Technical Regulations Customs Union (EAC) Flameproof
|
|
IM
|
Technical Regulations Customs Union (EAC) Intrinsic Safety
|
|
IN
|
Technical Regulations Customs Union (EAC) FISCO Intrinsic Safety
|
|
KM
|
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety
|
|
KA
|
ATEX and Canada Flameproof, Intrinsically Safe, Division 2
|
|
KB
|
USA and Canada Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
|
|
KC
|
USA and ATEX Explosion-proof, Intrinsically Safe, Division 2
|
|
KD
|
USA, Canada, and ATEX Explosion-proof, Intrinsically Safe
|
|
KG
|
USA, Canada, ATEX and IECEx FISCO Intrinsic Safety
|
|
KQ
|
USA, Canada, ATEX Intrinsic Safety Combination
|
|
KS
|
USA, Canada, IECEx, ATEX Explosion Proof, Intrinsically Safe, Dust, Non-Incendive, Type-N, Division 2
|
| Code |
Shipboard approvals Description
|
|
SBS
|
American Bureau of Shipping
|
|
SBV
|
Bureau Veritas (BV) Type Approval
|
|
SDN
|
Det Norske Veritas (DNV) Type Approval
|
|
SLL
|
Lloyds Register (LR) Type Approval
|
| Code |
Stainless steel tagging - Description
|
|
Y2
|
316 SST nameplate, top tag, wire-on tag(s), and fasteners
|
| Code |
Sensor fill fluid - Description
|
|
L1
|
Inert sensor fill fluid
|
| Code |
Display type - Description
|
|
M5
|
Plantweb™ LCD display
|
|
M7
|
Remote mount LCD display and interface, Plantweb housing, no cable, SST bracket
|
|
M8
|
Remote mount LCD display and interface, Plantweb housing, 50 ft. (15 m) cable, SST bracket
|
|
M9
|
Remote mount LCD display and interface, Plantweb housing, 100 ft. (31 m) cable, SST bracket
|
| Code |
Pressure testing - Description
|
|
P1
|
Hydrostatic testing with certificate
|
| Code |
Special cleaning - Description
|
|
P2
|
Cleaning for special services
|
|
P3
|
Cleaning for special services with testing for <1PPM chlorine/fluorine
|
Calibration certification
| Code |
Calibration certification - Description
|
|
Q4
|
Calibration certificate
|
|
QP
|
Calibration certificate and tamper evident seal
|
| Code |
Material traceability certification - Description
|
|
Q8
|
Material traceability certification per EN 10204 3.1
|
| Code |
Positive material identification (PMI) - Description
|
|
Q76
|
PMI verification and certificate
|
| Code |
Quality certification for safety - Description
|
| QT |
Safety certified to IEC 61508 with certificate of FMEDA |
| Code |
Transient protection - Description
|
|
T1
|
Transient terminal block
|
| Code |
Drinking water approval Description
|
|
DW
|
NSF drinking water approval
|
| Code |
Surface finish certification - Description
|
|
Q16
|
Surface finish certification for sanitary remote seals
|
| Code |
Toolkit total system performance reports - Description
|
|
QZ
|
Remote seal system performance calculation report
|
| Code |
Conduit electrical connectorz - Description
|
|
GE
|
M12, 4-pin, male connector (eurofast®)
|
|
GM
|
A size mini, 4-pin, male connector (minifast®)
|
NACE® certificate
| Code |
NACE® certificate - Description
|
|
Q15
|
Certificate of compliance to NACE MR0175/ISO 15156 for wetted materials
|
|
Q25
|
sCertificate of compliance to NACE MR0103 for wetted materials
|
Cold temperature
|
Code
|
Description
|
|
BR5
|
–58 °F (–50 °C) cold temperature operation
|
|
BR6
|
–76 °F (–60 °C) cold temperature operation
|
Figure 1 Below - Rosemount 306 In-line Style |
Figure 2 below - Rosemount 305 Coplanar™ Style
 |
Figure 3 below - Rosemount 304 conventional manifold wafer style
 |
Figure 4 below - Rosemount 304 three-valve manifold
 |
Designed and manufactured to maximize the performance of Rosemount transmitters. performance. ■ Factory assembly saves installation time and money. ■ Available in a variety of forms, materials, and configurations.
Technical specification
| Vibration effects |
When tested in accordance with the field requirements of IEC60770-1: 1999, or when the pipeline vibrates heavily (10-60 Hz 0.21 mm displacement peak amplitude / 60-2000 Hz 3g) Less than ±0.1% URL. |
| Power Supply Effects |
Less than ±0.005% of calibration range for each volt change. |
| Electromagnetic compatibility |
Meets all requirements for industrial environments according to EN61326 and NAMUR NE-21 Maximum deviation during EMC disturbances < 1% of the range. |
| Transient Protection (Option Code T1) |
Tested to IEEE C62.41.2-2002 Class B locations ■ 6 kV peak (0.5 µs - 100 kHz) ■ 3 kA peak (8 x 20 µs) ■ 6 kV peak (1.2 x 50 µs) |
| overpressure limit |
Rosemount 3051TG/TA ■ Range 0: 60 psi (4.14 bar) ■ Range 1: 750 psi (51.71 bar) Range 1: 750 psi (51.71 bar) ■ Range 2: 1500 psi (103.42 bar) ■ Range 3: 1600 psi (110.32 bar) ■ Range 4: 6000 psi (413.69 bar) ■ Range 5: 15000 psi (1034.21 bar) ■ Range 6: 24000 psi (1654.74 bar) |
| static pressure limit |
Rosemount 3051T Direct Connect ■ Range 0-4: 11016 psi (759.53 bar) ■ Range 5: 26016 psig (1793.74 bar) ■ Range 6: 46092 psi (3177.93 bar) |
| temperature limit |
Ambient Temperature ■ -40 to 185 °F (-40 to 85 °C) ■ With LCD display(1)(2): -40 to 176 °F (-40 to 80 °C) ■ With code BR5: -58 to 185 °F (-50 to 85 °C) ■ Options with code BR6: -76 to 185 °F (-60 to 85 °C) |
| Humidity Limit |
0-100% Relative Humidity |
| Process Connectors |
Rosemount 3051T ■ ½-14 NPT female threads ■ G½ A DIN 16288 male thread (ranges 1-4 only) ■ Model F-250-C autoclave (pressure relief 9/16-18 cap threads; ¼ OD high pressure hose 60° taper angle; range 5-6 transmitters only). |
safG
|