Autoclave Submersible Oil PumpOil pump
This product ships globally
SKU : P-1797
In Stock
(0 Reviews)
Autoclave Submersible Oil Pump
$0.00
Oil Pump : Oil pump
Quantity
Social share:

Social share:

You have 30 days to ask for a refund. All things on sale are final sale.


 

Autoclave Submersible Oil Pump

The coning and threading machine is furnished with a lubrication pump. This is used to supply cutting fluid to the points of cone cutting and threading. A sufficient supply of cutting fluid shall be maintained during machining operations for successful coning and threading.

An optional thermostatically controlled immersion heater is available for use in cold weather. Cutting fluid should be Parker AE Part No. P-1797.

For more details see the manual here

Recommendations

Very little service will be required by your pump if you follow the steps below:

  1. Never Start Pump if the pump itself if not completely submerged in oil
  2. Always use the cutting oil recommended by Autoclave Engineering. The Viscosity and Density are very important.
  3. Never Start the pump if oil is mixed with water or ice
  4. Never operate the pump if the oil temperature is below 20 degrees ( there is a heater for this scope).
  5. Always make sure that screen protection (tank) is in good condition to avoid that drilling chips entering inside the tank and then in inlet of the pump.
  6. If possible, avoid frequent start and stop of the pump.

 If, for any reason, the unit should fail to operate, follow the suggestions listed below:

  1.  Disconnect pump from electric current. Try it at another electrical outlet to make sure current is getting to the unit. If it still does not start:
  2. Remove the intake screen.
  3. Remove three (3) front screws as indicated by the arrows in Figure 1 and then remove the volute (cover over the impeller). (Do not remove other screws which may be exposed.)
  4. Lightly clean any corrosion or debris which may have clogged the volute or impeller. Use a brush and penetrating oil and lightly scrape away any deposits. Do not scratch the painted surface.
  5. Turn the impeller by hand to make sure it turns freely. While keeping the impeller from touching any thing, plug the unit in to see if the impeller will turn.
  6. If it does, re-install the volute, three (3) screws and inlet screen.
  7. This machine is designed to be operated under clean and dry conditions. Operating environment temperatures should not be below 32°F (0°C) or greater than 100°F (38°C).

If for any reason these operations do not restore the pump to full service, contact the little Giant Pump Company or it's authorized service center, or you can contact us directly to try to resolve the issue.

NOTE 1: DO NOT, IN ANY CASE, OPEN THE SEALED PORTION OF THE UNIT OR REMOVE SCREWS OTHER THAN SHOWN BY ARROWS IN ILLUSTRATION #1.

NOTE 2: DO NOT CUT THE ELECTRIC CORD OFF THE PUMP OR SHORTEN IT WHEN REMOVING THE PUMP. ONLY DISCONNECT PUMP FROM IT’S ORIGINAL CONNECTION.

NOTE 3: VIOLATIONS OF THESE PROVISIONS OR THOSE SHOWN IN THE LITTLE GIANT PUMP SERVICE GUIDE WILL VIOLATE THE WARRANTY ON THE UNIT.

NOTE 4: CONNECT TO SAME SERVICE VOLTAGE AS SHOWN ON THE PUMP.

NOTE 5: OPERATION OF OIL BELOW 65ºF (18.3ºC) THE HEATER IS REQUIRED.

CONDITIONS: This unit is designed to circulate light oils and other mild liquids. It will operate under more severe conditions also, but the warranty in such cases will be subject to approval by the factory.

 

No reviews yet. Be the first to review this product.

Frequently Bought

favicon bacd

+(39) 347 051 5328

Italy - Kazakhstan

09.00am to 18.00pm

About

We offer the best and economical solutions, backed by 27+ years of experience and international standards knowledge, echnological changes, and industrial systems.

Marketing Materials

Spring Renovation
Industry
US Gas Company
Construct
Plus Project
Vam Drilling Service
X Project
X Project
Cabrrus Training

Marketing Materials1

Spring Renovation
Industry
US Gas Company
Construct
Plus Project
Vam Drilling Service
ultrasonic sensor
ultrasonic sensor
Cabrrus Training