You have 30 days to ask for a refund. All things on sale are final sale.
Order Details
Model Code: FP15 Interface valve - Manifold Mount (External Pilot) |
|||
| Operator | Code | Max Pilot Pressure | Max. Valve Pressure |
| for more details see pdf here | |||
| Low Pressure Pilot (Piston) |
L1 | 10 bar | 414 bar |
| L1A | 19 bar | 690 bar | |
| L2 | 10 bar | 690 bar | |
| L3 | 7 bar | 690 bar | |
| L9 | 10 bar | 900 bar | |
| L10 | 10 bar | 1035 bar | |
| L11 | 10 bar | 690 bar | |
| High Pressure Pilot (Direct Acting) |
H1 | 240 bar | 690 bar |
| H2 | 690 bar | 690 bar | |
| DH2 | 690 bar | 690 bar | |
| H2 operating press ure applies to all models (pg4) |
FB VH1 | H.P. Pi lot Stage Frangible Bulb valves |
345 bar |
| FB VH2 | 518 bar | ||
| FB VH3 | 690 bar | ||
| H2 operating pressure applies to all models (pg4) |
H1 | ML(X) and MLP(X) options only |
345 bar |
| H2 | 518 bar | ||
| H3 | 690 bar | ||
| Connections | M | Subbase mounting | |
| 04 | 1/4 NP T body ported - FBVHx & Hx only | ||
| 06 | 3/8 NP T body ported | ||
| 38MP | 3/8 MP body ported (non standard) - L9 & L10 ONLY | ||
| Configura tion | 22 | 2 - way, 2 - position | Normally closed (NC) unless specified NO see options |
| 32 | 3 - way, 2 - position | ||
| O-ring Material | S | Nitrile (standard) (-30ºC to +130ºC) | |
| V | Viton (-20ºC to +180ºC) | ||
| SA | Nitrile (Low Temperature) (-36ºC to +180ºC) | ||
FBVH’X unit only |
For more details see PDF here | ||
| BULB COLOUR |
TEMPER ATURE RANGE Deg.C |
||
| 57C | Orange | 57 (Tol +/- 3.5%) | |
| 68C | Red | 68 (Tol +/- 3.5%) | |
| 79C | Yellow | 79 (Tol +/- 3.5%) | |
| 93C | Green | 93 (Tol +/- 3.5%) | |
| 141C | Blue | 141 (Tol +/- 3.5%) | |
| 182C | Mauve | 182 (Tol +/- 3.5%) | |
| Options | G | 150 bar gas , max valve press ure (L & H opera tors) | |
| H2S | NACE MR-01-75 Consult Bifold Fl uidpower | ||
| K6 | BSPP Ported | ||
| MSO | Manual screw down overr ide (L & H opera tors) | ||
| SI | Status Indicator | ||
| NO | Normally Open | ||
| Options1 | EP | External pilot supply | FBVH ‘x’, H’x’... ML(x) H’x’... MLP(x) only |
| EPT | External pilot supply and tank | ||
| Options2 | ML(X) | Manual Reset | High Press ure Pi lot Stage opera tor H1, H2 & H3 only |
| ML P(X) | Panel Mount Manual Reset | ||
We offer the best and economical solutions, backed by 27+ years of experience and international standards knowledge, echnological changes, and industrial systems.